Description
FEP, MFA, PFA (ENG)

Type: twisted, concentric or solid conductors, tinned or untinned, of silver-plated copper, nickel-plated and pure nickel.
International symbol: EFF, MFA, PFA (VDE 0207, VDE 0295).
Rated voltage: 300/500 V.
Field of use: in aviation, in the military or naval field, and especially in the field of electronics and household electrical appliances. Insulating materials give the conductor thermal resistance to the action of chemical agents, as well as a special mechanical and electrical resistance.
construction:
Conductor: silver-plated copper, nickel-plated copper or pure nickel, flexible, twisted, concentric or solid.
Insulation: EFF, MFA, PFA.
Ambient temperature: posed: FEP – 100 ° C to + 205 ° C, MFA -100 ° C to + 240 ° C, PFA -100 ° C to + 260 ° C.
International symbol: EFF, MFA, PFA (VDE 0207, VDE 0295).
Rated voltage: 300/500 V.
Field of use: in aviation, in the military or naval field, and especially in the field of electronics and household electrical appliances. Insulating materials give the conductor thermal resistance to the action of chemical agents, as well as a special mechanical and electrical resistance.
construction:
Conductor: silver-plated copper, nickel-plated copper or pure nickel, flexible, twisted, concentric or solid.
Insulation: EFF, MFA, PFA.
Ambient temperature: posed: FEP – 100 ° C to + 205 ° C, MFA -100 ° C to + 240 ° C, PFA -100 ° C to + 260 ° C.
Technical parameters:
Section | Construction | Nominal section | Electrical resistance at 20°C | Min. external diameter | Max. external diameter |
---|---|---|---|---|---|
(AWG) | (mm) | (mm2) | (Ω/km) | (mm) | (mm) |
26 | 1×0,40 | 0,13 | 148,0 | 0,78 | 0,82 |
26 | 7×0.16 | 0,14 | 137,0 | 0,88 | 0,92 |
26 | 19×0.10 | 0,15 | 137,0 | 0,88 | 0,92 |
24 | 1×0.51 | 0,20 | 92,50 | 0,89 | 0,93 |
24 | 7×0,20 | 0,22 | 86,20 | 0,98 | 1,02 |
24 | 19×0.13 | 0,24 | 86,20 | 1,03 | 1,07 |
22 | 1×0,65 | 0,33 | 57,50 | 1,03 | 1,07 |
22 | 7×0.25 | 0,35 | 53,60 | 1,18 | 1,22 |
22 | 19×0,16 | 0,38 | 53,60 | 1,18 | 1,22 |
20 | 1×0,81 | 0,52 | 37,10 | 1,19 | 1,23 |
20 | 7×0,32 | 0,57 | 33,70 | 1,38 | 1,45 |
20 | 19×0,20 | 0,61 | 33,70 | 1,38 | 1,45 |
18 | 1×1,02 | 0,82 | 23,10 | 1,40 | 1,44 |
18 | 7×0,40 | 090 | 21,10 | 1,63 | 1,67 |
18 | 19×0,25 | 0,97 | 21,10 | 1,63 | 1,67 |
16 | 1×1,30 | 1,31 | 14,60 | 1,68 | 1,72 |
16 | 19×0,29 | 1,23 | 15,60 | 1,83 | 1,87 |
14 | 1×1,63 | 2,08 | 9,20 | 2,01 | 2,05 |
14 | 19×0,36 | 1,94 | 9,90 | 2,20 | 2,24 |
12 | 1×2,05 | 3,31 | 5,70 | 2,43 | 2,47 |
12 | 19×2,05 | 3,08 | 6,20 | 2,65 | 2,70 |
PTFE (ENG)

Type: concentric or twisted conductor, with PTFE insulation.
International symbol: PTFE (VDE 7005).
Rated voltage: 300/500 V.
Field of use: used in dry or humid environments, in lighting equipment, in the automotive and shipbuilding industries, in household electrical appliances and in network systems. The thermal resistance allows the use of the conductor up to temperatures of 260 ° C, it also has a high mechanical resistance to chemical solvents. It has special dielectric characteristics.
construction:
Conductor: concentric or twisted, made of tinned copper, silver or nickel-plated, or pure nickel.
Insulation: polytetrafluoroethylene (PTFE) or fluorine polymers.
Ambient temperature: laid: CuR – 100 ° C to + 130 ° C, CuSn -100 ° C to + 180 ° C, CuAg -100 ° C to + 200 ° C, CuNi or Ni -100 ° C to + 250 ° C.
International symbol: PTFE (VDE 7005).
Rated voltage: 300/500 V.
Field of use: used in dry or humid environments, in lighting equipment, in the automotive and shipbuilding industries, in household electrical appliances and in network systems. The thermal resistance allows the use of the conductor up to temperatures of 260 ° C, it also has a high mechanical resistance to chemical solvents. It has special dielectric characteristics.
construction:
Conductor: concentric or twisted, made of tinned copper, silver or nickel-plated, or pure nickel.
Insulation: polytetrafluoroethylene (PTFE) or fluorine polymers.
Ambient temperature: laid: CuR – 100 ° C to + 130 ° C, CuSn -100 ° C to + 180 ° C, CuAg -100 ° C to + 200 ° C, CuNi or Ni -100 ° C to + 250 ° C.
Technical parameters:
Section | Internal diameter | Insulation thickness | External diameter | Aprox. mass |
---|---|---|---|---|
(mm2) | (mm) | (mm) | (mm) | (kg/km) |
0,50 | 0,21 | 0,30 | 1,50 | 6,90 |
0,75 | 0,21 | 0,30 | 1,75 | 9,30 |
1,00 | 0,21 | 0,30 | 1,85 | 12,0 |
1,50 | 0,26 | 0,30 | 2,15 | 16,9 |
2,50 | 0,26 | 0,35 | 2,70 | 29,2 |
SiD, SiF, FG4/2, UG4/2 (ENG)

Type: conductor with silicone rubber insulation.
International symbol: SiD, SiF, FG4 / 2, UG4 / 2 (VDE 0250).
Rated voltage: 300/500 V, up to 1500 V.
Field of use: in places with high temperatures, when connecting control cabinets or equipment, also having good mechanical properties.
construction:
Conductor: copper, single-wire (SiD) or multi-wire (SIF) tinned, single-wire (FG4 / 2) or multi-wire (UG4 / 2) non-tinned.
Insulation: silicone rubber.
Ambient temperature: laid -40 ° C to + 180 ° C, moving -25 ° C to + 180 ° C, maximum conductor temperature: + 220 ° C.
International symbol: SiD, SiF, FG4 / 2, UG4 / 2 (VDE 0250).
Rated voltage: 300/500 V, up to 1500 V.
Field of use: in places with high temperatures, when connecting control cabinets or equipment, also having good mechanical properties.
construction:
Conductor: copper, single-wire (SiD) or multi-wire (SIF) tinned, single-wire (FG4 / 2) or multi-wire (UG4 / 2) non-tinned.
Insulation: silicone rubber.
Ambient temperature: laid -40 ° C to + 180 ° C, moving -25 ° C to + 180 ° C, maximum conductor temperature: + 220 ° C.
Technical parameters:
Section | Colour | External diameter | Construction | Copper mass | Total mass |
---|---|---|---|---|---|
(mm2) | (mm) | (mm) | (kg/km) | (kg/km) | |
SiD | |||||
0,5 | m,n,a,r | 1,8 | 1×0,80 | 5 | 8 |
0,75 | m,al,n,a,r,gr,v/g | 2 | 1×0,98 | 7,5 | 10 |
1 | m,al,n,a,r,v/g | 2,2 | 1×1,13 | 10 | 13 |
1,5 | m,al,n,a,r,gr,v/g | 2,6 | 1×1,38 | 15 | 20 |
2,5 | m,n,a,r,v/g | 3,2 | 1×1,78 | 25 | 32 |
4 | n,a,v/g | 3,7 | 1×2,26 | 40 | 48 |
6 | m,n,a,r | 4,2 | 1×2,76 | 60 | 68 |
10 | n | 5,4 | 1×3,57 | 100 | 116 |
SiF | |||||
0,5 | m,al,n,a,r,gr,v/g | 1,9 | 16×0,21 | 5 | 8 |
0,75 | m,al,n,a,r,gr,v/g | 2,2 | 24×0,21 | 7,5 | 11 |
1 | m,al,n,a,r,gr,v/g | 2,3 | 32×0,21 | 10 | 14 |
1,5 | m,al,n,a,r,gr,v/g | 2,8 | 30×0,26 | 15 | 20 |
2,5 | m,al,n,a,r,gr,v/g | 3,4 | 50×0,26 | 25 | 32 |
4 | m,al,n,a,r,gr,v/g | 4 | 56×0,31 | 40 | 49 |
6 | m,al,n,a,r,gr,v/g | 4,7 | 84×0,31 | 60 | 70 |
10 | m,al,n,a,r,gr,v/g | 6,8 | 80×0,41 | 100 | 124 |
16 | m,n,a,r,gr,v/g | 7,8 | 128×0,41 | 160 | 188 |
25 | m,n,a,a,v/g | 9,7 | 200×0,41 | 250 | 292 |
35 | M,n | 10,9 | 280×0,41 | 350 | 391 |
50 | m,n | 13,6 | 400×0,41 | 500 | 561 |
70 | m,n | 15,6 | 356×0,51 | 700 | 761 |
95 | n | 18 | 485×0,51 | 950 | 1042 |
120 | n | 19,5 | 614×0,51 | 1200 | 1296 |
150 | n | 21,9 | 765×0,51 | 1500 | 1612 |
185 | n | 24,8 | 944×0,51 | 1850 | 1974 |
240 | N | 26,7 | 1225×0,51 | 2400 | 2553 |
SiD/GL, SiF/GL, UG4T2/2, FG4T2/2 (ENG)

Type: copper conductor with silicone rubber insulation and protected with fiberglass braid.
International symbol: SiF / GL, SiD / GL, FG4T2 / 2, UG4T2 / 2 (VDE 0250).
Rated voltage: 300/500 V.
Field of use: in places with high temperatures, when connecting control cabinets or equipment, also having good mechanical properties.
construction:
Conductor: copper, single-wire (SiD / GL) or multi-wire (SiF / GL) tinned, twisted; single-wire (UG4T2 / 2) or multi-wire (FG4T2 / 2) unstamped, twisted, particularly flexible.
Insulation: made of silicone rubber (2G11), protected with a fiberglass braid.
Ambient temperature: laid -40 ° C to + 180 ° C, moving -25 ° C to + 180 ° C, maximum conductor temperature: + 220 ° C.
International symbol: SiF / GL, SiD / GL, FG4T2 / 2, UG4T2 / 2 (VDE 0250).
Rated voltage: 300/500 V.
Field of use: in places with high temperatures, when connecting control cabinets or equipment, also having good mechanical properties.
construction:
Conductor: copper, single-wire (SiD / GL) or multi-wire (SiF / GL) tinned, twisted; single-wire (UG4T2 / 2) or multi-wire (FG4T2 / 2) unstamped, twisted, particularly flexible.
Insulation: made of silicone rubber (2G11), protected with a fiberglass braid.
Ambient temperature: laid -40 ° C to + 180 ° C, moving -25 ° C to + 180 ° C, maximum conductor temperature: + 220 ° C.
Technical parameters:
Section | External diameter | Construction | Copper mass | Total mass |
---|---|---|---|---|
(mm2) | (mm) | (mm) | (kg/km) | (kg/km) |
0,5 | 2,4 | 16×0,21 | 5 | 12 |
0,75 | 2,7 | 24×0,21 | 7,5 | 15 |
1 | 2,8 | 32×0,21 | 10 | 18 |
1,5 | 3,3 | 30×0,26 | 15 | 26 |
2,5 | 3,9 | 50×0,26 | 25 | 38 |
4 | 4,5 | 56×0,31 | 40 | 55 |
6 | 5,2 | 84×0,31 | 60 | 76 |
10 | 7,3 | 80×0,41 | 100 | 136 |
16 | 8,3 | 128×0,41 | 160 | 200 |
25 | 10,2 | 200×0,41 | 250 | 311 |
35 | 11,4 | 280×0,41 | 350 | 412 |
50 | 14,1 | 400×0,41 | 500 | 583 |
70 | 16,1 | 356×0,51 | 700 | 798 |
95 | 18,5 | 495×0,51 | 950 | 1073 |
120 | 20 | 614×0,51 | 1200 | 1329 |
SiHF, FG4G4/2 (ENG)

Type: copper conductors with silicone rubber insulation.
International symbol: SiHF, FG4G4 / 2 (VDE 0250).
Rated voltage: 300/500 V.
Field of use: in dry or humid places, but also outdoors, in places with low mechanical stress.
construction:
Conductor: made of extremely flexible, twisted, tinned (SiHF) or untinned (FG4G4 / 2) copper.
Insulation: the colored bundles, which also contain the green-yellow color, are insulated with silicone rubber.
Sheath: brown to red silicone rubber.
Ambient temperature: laid -40 ° C to + 180 ° C, moving -25 ° C to + 180 ° C, maximum conductor temperature: + 220 ° C.
International symbol: SiHF, FG4G4 / 2 (VDE 0250).
Rated voltage: 300/500 V.
Field of use: in dry or humid places, but also outdoors, in places with low mechanical stress.
construction:
Conductor: made of extremely flexible, twisted, tinned (SiHF) or untinned (FG4G4 / 2) copper.
Insulation: the colored bundles, which also contain the green-yellow color, are insulated with silicone rubber.
Sheath: brown to red silicone rubber.
Ambient temperature: laid -40 ° C to + 180 ° C, moving -25 ° C to + 180 ° C, maximum conductor temperature: + 220 ° C.
Technical parameters:
Section | External diameter | Construction | Copper mass | Total mass | ||
---|---|---|---|---|---|---|
(mm2) | (mm) | (mm) | (kg/km) | (kg/km) | ||
2 | x | 0,75 | 6,4 | 24×0,21 | 15 | 57 |
3 | x | 0,75 | 6,8 | 24×0,21 | 22,5 | 66 |
4 | x | 0,75 | 7,8 | 24×0,21 | 30 | 67 |
5 | x | 0,75 | 8,5 | 24×0,21 | 37,5 | 105 |
7 | x | 0,75 | 9,5 | 24×0,21 | 52,5 | 130 |
2 | x | 1 | 6,6 | 32×0,21 | 20 | 64 |
3 | x | 1 | 7,4 | 32×0,21 | 30 | 81 |
4 | x | 1 | 8 | 32×0,21 | 40 | 100 |
5 | x | 1 | 8,8 | 32×0,21 | 50 | 121 |
7 | x | 1 | 9,8 | 32×0,21 | 70 | 151 |
2 | x | 1,5 | 8 | 30×0,26 | 30 | 87 |
3 | x | 1,5 | 8,3 | 30×0,26 | 45 | 104 |
4 | x | 1,5 | 9 | 30×0,26 | 60 | 127 |
5 | x | 1,5 | 9,8 | 30×0,26 | 75 | 148 |
6 | x | 1,5 | 10,6 | 30×0,26 | 90 | 181 |
7 | x | 1,5 | 10,9 | 30×0,26 | 105 | 198 |
8 | x | 1,5 | 11,7 | 30×0,26 | 120 | 240 |
12 | x | 1,5 | 14,5 | 30×0,26 | 180 | 353 |
16 | x | 1,5 | 16,7 | 30×0,26 | 240 | 445 |
24 | x | 1,5 | 21 | 30×0,26 | 360 | 723 |
2 | x | 2,5 | 9,5 | 50×0,26 | 50 | 137 |
3 | x | 2,5 | 10 | 50×0,26 | 75 | 164 |
4 | x | 2,5 | 11 | 50×0,26 | 100 | 200 |
5 | x | 2,5 | 11,9 | 50×0,26 | 125 | 240 |
7 | x | 2,5 | 13,1 | 50×0,26 | 175 | 300 |
12 | x | 2,5 | 18 | 50×0,26 | 300 | 573 |
2 | x | 4 | 11,3 | 50×0,31 | 80 | 191 |
3 | x | 4 | 11,9 | 50×0,31 | 120 | 248 |
4 | x | 4 | 13,3 | 50×0,31 | 160 | 329 |
5 | x | 4 | 15 | 50×0,31 | 200 | 399 |
7 | x | 4 | 16,2 | 50×0,31 | 280 | 486 |
3 | x | 6 | 14,2 | 84×0,31 | 180 | 351 |
4 | x | 6 | 16,2 | 84×0,31 | 240 | 462 |
5 | x | 6 | 17,7 | 84×0,31 | 300 | 547 |
7 | x | 6 | 19,8 | 84×0,31 | 420 | 694 |
4 | x | 10 | 21,4 | 80×0,41 | 400 | 709 |
4 | x | 16 | 24 | 128×0,41 | 640 | 1014 |
4 | x | 25 | 27,5 | 200×0,41 | 1000 | 1557 |
SiHF/GL, FG4G4T2/2 (ENG)

Type: copper conductors with silicone rubber insulation protected with fiberglass braid.
International symbol: SIHF / GL, FG4G4T2 / 2 (VDE 0250).
Rated voltage: 300/500 V.
Field of use: for powering electrical installations at a constant temperature of 180 ° C (max. 200 ° C), not being protected during handling.
construction:
Conductor: flexible, tinned (SiFH / GL) or untinned (FG4G4T2 / 2) copper.
Insulation: silicone rubber on each bundle.
Sheath: made of brown to red silicone rubber, protected with a fiberglass braid.
Ambient temperature: laid -60 ° C to + 180 ° C, maximum conductor temperature: + 200 ° C.
International symbol: SIHF / GL, FG4G4T2 / 2 (VDE 0250).
Rated voltage: 300/500 V.
Field of use: for powering electrical installations at a constant temperature of 180 ° C (max. 200 ° C), not being protected during handling.
construction:
Conductor: flexible, tinned (SiFH / GL) or untinned (FG4G4T2 / 2) copper.
Insulation: silicone rubber on each bundle.
Sheath: made of brown to red silicone rubber, protected with a fiberglass braid.
Ambient temperature: laid -60 ° C to + 180 ° C, maximum conductor temperature: + 200 ° C.
Technical parameters:
Section | External diameter | Construction | Copper mass | Total mass | ||
---|---|---|---|---|---|---|
(mm2) | (mm) | (mm) | (kg/km) | (kg/km) | ||
2 | x | 0,75 | 6,90 | 24×0,20 | 14,4 | 65 |
2 | x | 1 | 7,10 | 32×0,20 | 19,0 | 76 |
2 | x | 1,5 | 8,30 | 30×0,25 | 29,0 | 98 |
2 | x | 2,5 | 9,60 | 50×0,25 | 48,0 | 138 |
2 | x | 4 | 11,70 | 56×0,30 | 77,0 | 240 |
2 | x | 6 | 13,50 | 84×0,30 | 115,0 | 297 |
3 | x | 0,75 | 7,20 | 24×0,20 | 21,6 | 75 |
3 | x | 1 | 7,90 | 32×0,20 | 29,0 | 90 |
3 | x | 1,5 | 8,40 | 30×0,25 | 43,0 | 116 |
3 | x | 2,5 | 10,10 | 50×0,25 | 72,0 | 172 |
3 | x | 4 | 11,80 | 56×0,30 | 115,0 | 247 |
3 | x | 6 | 14,60 | 84×0,30 | 173,0 | 385 |
4 | x | 0,75 | 8,20 | 24×0,20 | 29,0 | 97 |
4 | x | 1 | 8,50 | 32×0,20 | 38,0 | 113 |
4 | x | 1,5 | 9,20 | 30×0,25 | 58,0 | 143 |
4 | x | 2,5 | 11,00 | 50×0,25 | 96,0 | 213 |
4 | x | 4 | 13,50 | 56×0,30 | 154,0 | 325 |
4 | x | 6 | 16,30 | 84×0,30 | 230,0 | 548 |
5 | x | 0,75 | 9,00 | 24×0,20 | 36,0 | 116 |
5 | x | 1 | 9,20 | 32×0,20 | 48,0 | 135 |
5 | x | 1,5 | 10,10 | 30×0,25 | 72,0 | 171 |
5 | x | 2,5 | 12,00 | 50×0,25 | 120,0 | 260 |
5 | x | 4 | 15,00 | 56×0,30 | 192,0 | 402 |
5 | x | 6 | 17,50 | 84×0,30 | 288,0 | 570 |
6 | x | 0,75 | 9,70 | 24×0,20 | 43,0 | 133 |
6 | x | 1 | 10,50 | 32×0,20 | 58,0 | 155 |
6 | x | 1,5 | 10,90 | 32×0,25 | 86,0 | 192 |
6 | x | 2,5 | 13,50 | 50×0,25 | 144,0 | 298 |
6 | x | 4 | 16,60 | 56×0,30 | 230,0 | 451 |
7 | x | 0,75 | 9,70 | 24×0,20 | 50,0 | 147 |
7 | x | 1 | 10,50 | 32×0,20 | 67,0 | 172 |
7 | x | 1,5 | 10,90 | 30×0,25 | 101,0 | 214 |
7 | x | 2,5 | 13,50 | 50×0,25 | 168,0 | 334 |
7 | x | 4 | 16,60 | 56×0,30 | 269,0 | 520 |
0°C.
SiHFP (ENG)

Type: copper conductors with silicone rubber insulation, steel braid sheath.
International symbol: SiHFP (VDE 0250).
Rated voltage: 300/500 V.
Field of use: in dry and humid places or outdoors, in places with high temperatures, in applications with low mechanical stress.
construction:
Conductor: made of very flexible, tinned copper.
Insulation: the colored bundles, which also contain the green-yellow color, are insulated with silicone rubber.
Sheath: made of brown to red silicone rubber, over which a steel braid coating is applied.
Ambient temperature: laid -40 ° C to + 180 ° C, moving -25 ° C to + 180 ° C, maximum conductor temperature: + 220 ° C.
International symbol: SiHFP (VDE 0250).
Rated voltage: 300/500 V.
Field of use: in dry and humid places or outdoors, in places with high temperatures, in applications with low mechanical stress.
construction:
Conductor: made of very flexible, tinned copper.
Insulation: the colored bundles, which also contain the green-yellow color, are insulated with silicone rubber.
Sheath: made of brown to red silicone rubber, over which a steel braid coating is applied.
Ambient temperature: laid -40 ° C to + 180 ° C, moving -25 ° C to + 180 ° C, maximum conductor temperature: + 220 ° C.
Technical parameters:
Section | External diameter | Construction | Copper mass | Total mass | ||
---|---|---|---|---|---|---|
(mm2) | (mm) | (mm) | (kg/km) | (kg/km) | ||
2 | x | 0,75 | 7,5 | 24×0,21 | 15 | 107 |
3 | x | 0,75 | 7,8 | 24×0,21 | 22,5 | 114 |
4 | x | 0,75 | 9 | 24×0,21 | 30 | 120 |
5 | x | 0,75 | 9,8 | 24×0,21 | 37,5 | 175 |
7 | x | 0,75 | 10,6 | 24×0,21 | 52,5 | 208 |
2 | x | 1 | 7,6 | 32×0,21 | 20 | 121 |
3 | x | 1 | 8,5 | 32×0,21 | 30 | 145 |
4 | x | 1 | 9,3 | 32×0,21 | 40 | 158 |
5 | x | 1 | 10,2 | 32×0,21 | 50 | 201 |
7 | x | 1 | 11,3 | 32×0,21 | 70 | 231 |
2 | x | 1,5 | 9 | 30×0,26 | 30 | 153 |
3 | x | 1,5 | 9,3 | 30×0,26 | 45 | 168 |
4 | x | 1,5 | 10,2 | 30×0,26 | 60 | 208 |
5 | x | 1,5 | 11,5 | 30×0,26 | 75 | 235 |
7 | x | 1,5 | 12 | 30×0,26 | 105 | 293 |
12 | x | 1,5 | 14,9 | 30×0,26 | 180 | 385 |
2 | x | 2,5 | 10,7 | 50×0,26 | 50 | 221 |
3 | x | 2,5 | 11,2 | 50×0,26 | 75 | 224 |
4 | x | 2,5 | 12,2 | 50×0,26 | 100 | 295 |
5 | x | 2,5 | 13 | 50×0,26 | 125 | 343 |
7 | x | 2,5 | 14 | 50×0,26 | 175 | 416 |
2 | x | 4 | 12,5 | 50×0,31 | 80 | 292 |
3 | x | 4 | 13,1 | 50×0,31 | 120 | 338 |
4 | x | 4 | 14,4 | 50×0,31 | 160 | 445 |
5 | x | 4 | 16,2 | 50×0,31 | 200 | 526 |
3 | x | 6 | 15,7 | 84×0,31 | 180 | 415 |
4 | x | 6 | 17,7 | 84×0,31 | 240 | 602 |
5 | x | 6 | 19,2 | 84×0,31 | 300 | 697 |
4 | x | 10 | 22,6 | 80×0,41 | 400 | 880 |
4 | x | 16 | 25,2 | 128×0,41 | 640 | 1220 |
4 | x | 25 | 30,4 | 200×0,41 | 1000 | 1710 |
SiFCuSi (ENG)

Type: copper conductors with silicone rubber insulation and shielding with copper braid.
International symbol: SiHFP (VDE 0250).
Rated voltage: 300/500 V.
Field of use: in dry and humid places or outdoors, in places with high temperatures, in applications with low mechanical stress, where shielding is needed, against frequency disturbances.
construction:
Conductor: twisted and tinned multifilament copper.
Insulation: made of silicone rubber on each bundle, they are protected with a PETP foil.
Shielding: made of stanata copper braid.
Sheath: brown to red silicone rubber.
Ambient temperature: laid -40 ° C to + 180 ° C, moving -25 ° C to + 180 ° C, maximum conductor temperature: + 220 ° C.
International symbol: SiHFP (VDE 0250).
Rated voltage: 300/500 V.
Field of use: in dry and humid places or outdoors, in places with high temperatures, in applications with low mechanical stress, where shielding is needed, against frequency disturbances.
construction:
Conductor: twisted and tinned multifilament copper.
Insulation: made of silicone rubber on each bundle, they are protected with a PETP foil.
Shielding: made of stanata copper braid.
Sheath: brown to red silicone rubber.
Ambient temperature: laid -40 ° C to + 180 ° C, moving -25 ° C to + 180 ° C, maximum conductor temperature: + 220 ° C.
Technical parameters:
Section | External diameter | Construction | Copper mass | Total mass | ||
---|---|---|---|---|---|---|
(mm2) | (mm) | (mm) | (kg/km) | (kg/km) | ||
2 | x | 0,75 | 7,6 | 24×0,21 | 45 | 76 |
2 | x | 1 | 7,8 | 32×0,21 | 50 | 83 |
2 | x | 1,5 | 8,8 | 30×0,26 | 69 | 108 |
2 | x | 2,5 | 10 | 50×0,26 | 93 | 141 |
3 | x | 0,75 | 7,9 | 24×0,32 | 53 | 90 |
3 | x | 1 | 8,1 | 32×0,21 | 63 | 100 |
3 | x | 1,5 | 9,2 | 30×0,26 | 85 | 131 |
3 | x | 2,5 | 10,5 | 50×0,26 | 127 | 184 |
4 | x | 0,75 | 8,5 | 24×0,21 | 64 | 106 |
4 | x | 1 | 8,7 | 32×0,21 | 79 | 121 |
4 | x | 1,5 | 9,9 | 30×0,26 | 103 | 158 |
4 | x | 2,5 | 11,4 | 50×0,26 | 153 | 223 |
5 | x | 0,75 | 9,1 | 24×0,21 | 77 | 153 |
5 | x | 1 | 9,4 | 32×0,21 | 90 | 143 |
5 | x | 1,5 | 10,8 | 30×0,26 | 127 | 195 |
5 | x | 2,5 | 12,3 | 50×0,26 | 184 | 272 |
7 | x | 0,75 | 9,8 | 24×0,21 | 95 | 209 |
7 | x | 1 | 10,1 | 32×0,21 | 113 | 173 |
7 | x | 1,5 | 11,6 | 30×0,26 | 162 | 240 |
7 | x | 2,5 | 13,8 | 50×0,26 | 236 | 351 |
10 | x | 1,5 | 14,8 | 30×0,26 | 222 | 340 |
12 | x | 1,5 | 15,2 | 30×0,26 | 253 | 386 |
16 | x | 1,5 | 17,4 | 30×0,26 | 411 | 523 |
18 | x | 1,5 | 18,2 | 30×0,26 | 381 | 577 |